fold(P) fold(P) NAME fold - filter for folding lines SYNOPSIS fold [-bs][-w width][file...] DESCRIPTION The fold utility is a filter that shall fold lines from its input files, breaking the lines to have a maximum of width column positions (or bytes, if the -b option is specified). Lines shall be broken by the insertion of a such that each output line (referred to later in this section as a segment) is the maximum width pos- sible that does not exceed the specified number of col- umn positions (or bytes). A line shall not be broken in the middle of a character. The behavior is undefined if width is less than the number of columns any single character in the input would occupy. If the s, s, or s are encountered in the input, and the -b option is not spec- ified, they shall be treated specially: The current count of line width shall be decre- mented by one, although the count never shall become negative. The fold utility shall not insert a immediately before or after any . The current count of line width shall be set to zero. The fold utility shall not insert a immediately before or after any . Each encountered shall advance the column position pointer to the next tab stop. Tab stops shall be at each column position n such that n modulo 8 equals 1. OPTIONS The fold utility shall conform to the Base Definitions volume of IEEE Std 1003.1-2001, Section 12.2, Utility Syntax Guidelines. The following options shall be supported: -b Count width in bytes rather than column posi- tions. -s If a segment of a line contains a within the first width column positions (or bytes), break the line after the last such meet- ing the width constraints. If there is no meeting the requirements, the -s option shall have no effect for that output segment of the input line. -w width Specify the maximum line length, in column posi- tions (or bytes if -b is specified). The results are unspecified if width is not a positive deci- mal number. The default value shall be 80. OPERANDS The following operand shall be supported: file A pathname of a text file to be folded. If no file operands are specified, the standard input shall be used. STDIN The standard input shall be used only if no file oper- ands are specified. See the INPUT FILES section. INPUT FILES If the -b option is specified, the input files shall be text files except that the lines are not limited to {LINE_MAX} bytes in length. If the -b option is not specified, the input files shall be text files. ENVIRONMENT VARIABLES The following environment variables shall affect the execution of fold: LANG Provide a default value for the internationaliza- tion variables that are unset or null. (See the Base Definitions volume of IEEE Std 1003.1-2001, Section 8.2, Internationalization Variables for the precedence of internationalization variables used to determine the values of locale cate- gories.) LC_ALL If set to a non-empty string value, override the values of all the other internationalization variables. LC_CTYPE Determine the locale for the interpretation of sequences of bytes of text data as characters (for example, single-byte as opposed to multi- byte characters in arguments and input files), and for the determination of the width in column positions each character would occupy on a con- stant-width font output device. LC_MESSAGES Determine the locale that should be used to affect the format and contents of diagnostic mes- sages written to standard error. NLSPATH Determine the location of message catalogs for the processing of LC_MESSAGES . ASYNCHRONOUS EVENTS Default. STDOUT The standard output shall be a file containing a sequence of characters whose order shall be preserved from the input files, possibly with inserted s. STDERR The standard error shall be used only for diagnostic messages. OUTPUT FILES None. EXTENDED DESCRIPTION None. EXIT STATUS The following exit values shall be returned: 0 All input files were processed successfully. >0 An error occurred. CONSEQUENCES OF ERRORS Default. The following sections are informative. APPLICATION USAGE The cut and fold utilities can be used to create text files out of files with arbitrary line lengths. The cut utility should be used when the number of lines (or records) needs to remain constant. The fold utility should be used when the contents of long lines need to be kept contiguous. The fold utility is frequently used to send text files to printers that truncate, rather than fold, lines wider than the printer is able to print (usually 80 or 132 column positions). EXAMPLES An example invocation that submits a file of possibly long lines to the printer (under the assumption that the user knows the line width of the printer to be assigned by lp): fold -w 132 bigfile | lp RATIONALE Although terminal input in canonical processing mode requires the erase character (frequently set to ) to erase the previous character (not byte or column position), terminal output is not buffered and is extremely difficult, if not impossible, to parse cor- rectly; the interpretation depends entirely on the phys- ical device that actually displays/prints/stores the output. In all known internationalized implementations, the utilities producing output for mixed column-width output assume that a backs up one column position and outputs enough s to return to the start of the character when is used to provide local line motions to support underlining and emboldening operations. Since fold without the -b option is dealing with these same constraints, is always treated as backing up one column position rather than backing up one character. Historical versions of the fold utility assumed 1 byte was one character and occupied one column position when written out. This is no longer always true. Since the most common usage of fold is believed to be folding long lines for output to limited-length output devices, this capability was preserved as the default case. The -b option was added so that applications could fold files with arbitrary length lines into text files that could then be processed by the standard utilities. Note that although the width for the -b option is in bytes, a line is never split in the middle of a character. (It is unspecified what happens if a width is specified that is too small to hold a single character found in the input followed by a .) The tab stops are hardcoded to be every eighth column to meet historical practice. No new method of specifying other tab stops was invented. FUTURE DIRECTIONS None. SEE ALSO cut COPYRIGHT Portions of this text are reprinted and reproduced in electronic form from IEEE Std 1003.1, 2003 Edition, Standard for Information Technology -- Portable Operat- ing System Interface (POSIX), The Open Group Base Speci- fications Issue 6, Copyright (C) 2001-2003 by the Insti- tute of Electrical and Electronics Engineers, Inc and The Open Group. In the event of any discrepancy between this version and the original IEEE and The Open Group Standard, the original IEEE and The Open Group Standard is the referee document. The original Standard can be obtained online at http://www.open- group.org/unix/online.html . POSIX 2003 fold(P)